LIQUID RECEIVERS

The Liquid receiver presents vertical or horizontal version.
Normally the liquid receiver is sized following the heat exchanger’s volume and the refrigerant liquid volume.
The Liquid receiver must be mounted after the condenser coil in order to ensure the compensation of refrigerant volume variation.
The receiver is supplied perfectly clean, with hermetic closing..
VERTICAL LIQUID RECEIVERS
The Liquid receiver presents vertical or horizontal version.
Normally the liquid receiver is sized following the heat exchanger’s volume and the refrigerant liquid volume.
The Liquid receiver must be mounted after the condenser coil in order to ensure the compensation of refrigerant volume variation.
The receiver is supplied perfectly clean, with hermetic closing
General tolerances : +/- 5 – 10°C
Temperature: -10°C / +100°C
Maximum working pressure : 32 Bar – 45 bar

HORIZONTAL LIQUID RECEIVERS
The Liquid receiver presents vertical or horizontal version.
Normally the liquid receiver is sized following the heat exchanger’s volume and the refrigerant liquid volume.
The Liquid receiver must be mounted after the condenser coil in order to ensure the compensation of refrigerant volume variation.
The receiver is supplied perfectly clean, with hermetic closing.

General tolerances : +/- 5 – 10°C
Temperature: -10°C / +100°C
Maximum working pressure : 32 Bar – 45 bar
Compressor support:

UNIVERSAL LIQUID RECEIVERS
The Liquid receiver presents vertical or horizontal version.
Normally the liquid receiver is sized following the heat exchanger’s volume and the refrigerant liquid volume.
The Liquid receiver must be mounted after the condenser coil in order to ensure the compensation of refrigerant volume variation.
The receiver is supplied perfectly clean, with hermetic closing.

General tolerances : +/- 5 – 10°C
Temperature: -10°C / +100°C
Maximum working pressure : 32 Bar – 45 bar
Compressor support
Liquid Receivers ABR components
Vertical Liquid Receiver: Liquid receiver 1 - 1,5L  for all tyes of Freon's up to 45 bar
Vertical Liquid Receiver: Liquid receiver 2,4 - 14L  for all tyes of Freon's up to 45 bar
Vertical Liquid Receiver: Liquid receiver 18 - 30L  for all tyes of Freon's up to 45 bar
Vertical Liquid Receiver: Liquid receiver 30 - 90L  for all tyes of Freon's up to 45 bar
Horizontal Liquid Receiver: Liquid receiver 7 - 25L  for all tyes of Freon's up to 45 bar
Horizontal Liquid Receiver: Liquid receiver 30 - 90L  for all tyes of Freon's up to 45 bar
Universal Liquid Receiver: Liquid receiver 30 - 90L  for all tyes of Freon's up to 45 bar
Powered by webprojm.com 2023
Logo ABR Components
ABR Components srl, trade consulting for industrial refrigeration, HVAC, Freon and R744 low and high pressure applications
Privacy Policy
Cookie Policy
Contact Us
Address:
Via L.Savio 1 - 33080 Roveredo in Piano (PN)
VAT IT01688460938 |  +39 345 4605931 (Mob.)
Tel. 0434 312483
info@abrcomponents.eu


10 anni ABR